Resolves: tdf#122356 on row-activate click ok button
instead of proceeding directy to the ok response. Because there is
an additional handler installed in the okbutton to do extra stuff
that is needed to make this work
Change-Id: I9646ea6978533084c6c9c48b03806e46eaa49c33
Reviewed-on: https://gerrit.libreoffice.org/66047
Tested-by: Jenkins
Reviewed-by: Xisco Faulí <xiscofauli@libreoffice.org>
diff --git a/cui/source/tabpages/numfmt.cxx b/cui/source/tabpages/numfmt.cxx
index d3eb10e..344e381 100644
--- a/cui/source/tabpages/numfmt.cxx
+++ b/cui/source/tabpages/numfmt.cxx
@@ -1139,7 +1139,10 @@ IMPL_LINK(SvxNumberFormatTabPage, DoubleClickHdl_Impl, weld::TreeView&, rLb, voi
SelFormatHdl_Impl(&rLb);
if (SfxTabDialogController* pController = GetDialogController())
pController->getDialog()->response(RET_OK);
{
weld::Button& rOkButton = pController->GetOKButton();
rOkButton.clicked();
}
else
{
SfxSingleTabDialog* pParent = dynamic_cast<SfxSingleTabDialog*>(GetParentDialog());